Figure #3: Fireplace Framing Figure #4: Possible Chimney Configurations
FRAMING
The construction of the framing, facing, and mantel must be in accordance with the standards and the
following illustrations (figures 2 and 3):
Frame the fireplace using 2" × 3" (5 cm x 8 cm) or heavier lumber.
WARNING: COMBUSTIBLE FRAMING MATERIAL CANNOT BE USED IN THE SPACE
DIRECTLY ABOVE THE FIREPLACE, EXCEPT FOR THE STUDS ABOVE THE FACING
THAT SUPPORT THE FACING MATERIAL AND MANTEL. THIS AREA MUST REMAIN
EMPTY FOR A HEIGHT OF 7 (2,15 M) MEASURED FROM THE BASE OF THE
APPLIANCE.
Frame the fireplace with vertical studs at the sides of the fireplace running from floor to ceiling (see
figure 3). Position the studs back from the front edge of the fireplace, a space the thickness of the facing
material so that the facing can be installed flush with the fireplace facing (within limitations of figure 3). Frame
headers between the vertical studs only as follows:
Place 2" × 3" or 2" × 4" headers, only along the upper part of the front, side and back faces. Do not put
wood or any combustible material within the area above the fireplace except on the front facing.
Place headers only as required to support the facing and mantel.
WARNING:
DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER
MATERIALS.
WARNING:
THE FIREPLACE MUST NOT BE IN CONTACT WITH ANY INSULATION OR
LOOSE FILLING MATERIAL. COVER THE INSULATION WITH GYPROC PANELS
AROUND THE FIREPLACE.